My Digital Battery is reading
Hold! What is going on and how do I fix it?
For very different
reasons this can happen to
a Logic, Digital Logic, or Hytron battery that has never been recelled as
well as a battery that has been recelled. No matter if this
battery is an
OEM battery, or a recell with a new insert having battery cells
exceeding, exactly the same, or less quality, than OEM, the
battery cell is not the cause of this reading.
If your Anton Bauer Interactive chargers no longer recognize particular
Anton Bauer Logic or Hytron series batteries the battery inserts may still
be good and there is a cost saving resolution. Call for details.
Cadex and PAG analyzers use very sophisticated algorithms to
maintain your batteries and use a pulse charge to keep your batteries at
maximum capacity while on the analyzer. Because these analyzers are
high end analyzers and not sophisticated smart chargers they can charge
rechargeable batteries with temperature sensors, BUT do NOT require your
battery to have temperature sensors for proper charging, and they achieve
excellent battery performance.
Unlike smart chargers, Cadex and PAG analyzers do NOT require
any digital circuitry to analyze and properly charger your
batteries.
At Rathbone Energy
we verify every Digital Logic / Hytron type battery is reading properly on Anton
Bauer 2702 InterActive chargers with the DDM before sealing the
case and shipping your products back to you.
-
First trouble
shoot your battery.
-
Check the
contacts on your battery for corrosion that may or may not be
visible. If possible take a small delicate tool and scrape
the mushroom or button type contacts.
-
Follow up with
an eraser head if possible and then blow out any debris.
-
Be careful with
electronic contact cleaners. We recently had a new client
simply spray an electronic contact cleaner, under pressure and
very cold, on a warm battery. He broke the back plate. Not an easy thing to do.
-
If this does not
resolve your problem then it is a very high probability that your
defect is one of the following.
-
Internally in an
Anton Bauer Digital Propac, a particular wire is broken. The defective wire could
have been pinched or a solder connection broken.
-
The simple
solution is to replace the wire.
-
We have seen both
instances in never recelled and in previously recelled batteries.
-
Internally in an Anton Bauer
Digital or Hytron a sensor or board component has simply gone bad.
You insert needs to be transferred into another shell or you may purchase a
PAG analyzer.
-
We have seen both
instances in never recelled and in previously recelled batteries.
-
Many times we
receive batteries that have been previously recelled by other
vendors, some open this week and some not.
-
Frequently we find
wires in the harness that have been damaged while improperly
opening the case.
-
Sometimes they have
even twisted the wires together and wrapped them with tape.
-
Other times they
have attempted to re-wire the harness using improper color coding
such as blue on the ground and black on the temperature sensor
connection.
-
When opening a pack
that has never been opened we occasionally find a pinched wire or a loose
circuit board screw.
Nothing nor anyone is perfect. We replace the wire to keep
the battery from showing up again before it should.
-
If the wiring
harness is not secured properly before closing the case a solder
joint can be stressed. At Rathbone Energy we secure the
insert beyond industry standards. This helps prevent pinched
wires and stops the breaking of a solder joint on a thin 24-26
gauge wire.
-
A temperature sensor
in the battery wiring harness
is slightly out of calibration with your "Intelli" type charger sensing
technology.
This does not happen very often but can happen at any time. Sometimes they re-calibrate and sometimes this requires a temperature
harness / sensor replacement. If you own PAG analyzers this is never an
issue.
-
That is why the final test of
our recells, before sealing and after sealing your case, are completed
on Anton Bauer 2702 InterActive Chargers with the DDM for approval,
Then we ship
your fine product back to you.
-
If your charger insist on reading:
CCO, HOLD, or NON-LOGIC, these batteries will operate fine on a PAG or Cadex
analyzer.
-
Before installation we charge and test the
charge of our new battery inserts.
We use Only
CADEX, CHRISTIE, and PAG Battery Management Analyzers. (After a
battery is fully charged there is No continuous trickle charge on
these analyzers. They monitor the charge and supply a pulse
charge when necessary)
- After installation into your case the complete
battery is tested. Then we seal the case
and test each packs
voltage again through the pin connectors and finally on Anton
Bauer Quad 2702 InterActive chargers with the DDM module before shipping back
to you.
-
Notes:
Many times clients have battery packs that go dead or stop functioning
with their manufacturers brand smart charger. Thinking the batteries
are dead they place them on a shelf until they are ready to recell the
units.
The batteries actually go dead sitting on a shelf. The original
issue was actually communications between that battery and the OEM smart
charger. The batteries were actually fine and would have continued to
perform fine if charged on a Cadex or PAG analyzers.
- Hytron 50 Precautions
-
This link takes you away from rathboneenergy.com
Please hit your back button or bookmark our site before leaving.
-
To better understand
how your batteries learn see:
-
Anton Bauer's Manual
on Propac 14 and Trimpac 14 digital batteries:
-
Liquid Crystal Display
(LCD);
-
Read Manual Page numbers (9, 10 & 11), Adobe pdf page number
(13, 14 & 15)
- Link to Anton Bauer Digital Propac / Trimpac Manual :
http://www.antonbauer.com/downloads/dig_propac_14-dig_tripac_14.pdf
- Note: With their web site upgrades the above link sometimes
moves and we end up with a dead link. If it is a dead link
Search for the active link on their site.


Saturday, April 19, 2008 01:31:34 AM
Copyright Rathbone Energy, Inc.,
1990, All Rights Reserved.
Last Revised September 09, 2002
|
|